Pulmonary · clinical calculator
Light’s Criteria Calculator
Exudate or transudate? Enter the available pleural and serum measurements. Open the optional gradients or hematocrit assessment when relevant.
Pleural fluid analysis
Enter paired measurements
Paired serum and pleural samples should reflect the same clinical time point.
Light’s classification
Incomplete classification
No positive criterion yet; more measurements are needed. 0 of 3 criteria evaluable.
- Pleural / serum proteinNot evaluable (positive if >0.5)
- Pleural / serum LDHNot evaluable (positive if >0.6)
- Pleural LDH / serum LDH ULNNot evaluable (positive if >2/3)
Missing or invalid: Pleural fluid protein, Serum protein, Pleural fluid LDH, Serum LDH, Lab’s upper normal LDH value.
Any positive evaluable criterion indicates an exudate. All three must be evaluable and negative to call it transudative. Classification uses unrounded values.
Possible pseudoexudate after diuresis
Serum–pleural albumin gradient (preferred): enter both measurements.
Serum–pleural protein gradient (additional): enter both measurements.
These gradients are most useful when Light’s criteria indicate an exudate but heart failure, hepatic hydrothorax or diuresis suggests a transudative mechanism.
Neither gradient excludes infection, malignancy or another exudative cause. Light’s original classification stays unchanged.
Hemothorax assessment
Enter both hematocrits; peripheral blood hematocrit must be greater than zero.
Suspected hemothorax requires prompt clinical assessment.
Calculated locally. Inputs stay in this tab and are not sent in analytics. Reference ranges are software entry guardrails.
Educational use only. This tool and its outputs do not constitute medical advice, diagnosis, or treatment and do not replace clinical judgment. Independently verify the inputs, equations, assumptions, units, and outputs, and confirm that the tool is appropriate for your intended use before relying on a result.
Thoracentesis Labs: What Should I Send?
An indication-specific preparation checklist, not an automatic order set. Select only the studies needed for the clinical question. Nothing is selected by default.
Pleural pH: follow local laboratory collection instructions; use an appropriate blood-gas syringe, expel air and excess heparin, avoid local-anesthetic contamination, and analyze promptly (ideally within 1 hour) on a blood-gas analyzer. Select culture bottle inoculation when pleural infection is suspected and follow local specimen protocols.
How to Use Light’s Criteria
Enter pleural fluid and serum protein in g/dL, pleural and serum LDH in U/L, and the laboratory’s serum LDH upper limit of normal. Any one positive criterion identifies an exudate: protein ratio >0.5; LDH ratio >0.6; or pleural LDH >2/3 of the serum LDH ULN. Equality does not meet these strict cutoffs. Missing values allow partial calculation but cannot establish a transudate. [1][2]
Exudate vs Transudate
Exudates commonly accompany pneumonia or pleural infection, malignancy, pulmonary embolism and inflammatory disease. Transudates commonly reflect systemic pressure or protein-balance disturbances, including heart failure, cirrhosis with hepatic hydrothorax, and nephrotic syndrome. The classification guides investigation; it does not identify a cause. [1][2]
Pseudoexudates After Diuresis
Diuresis can concentrate pleural protein and LDH in an effusion caused by heart failure or hepatic hydrothorax. If Light’s result is exudative despite a plausible transudative mechanism, gradients can provide supporting evidence. They never replace the Light’s result or exclude a coexisting exudative process. [3]
Serum–Pleural Albumin Gradient
Subtract pleural albumin from serum albumin. A gradient >1.2 g/dL supports a possible transudative mechanism. The serum–pleural total protein gradient >3.1 g/dL is an additional measure. Albumin is preferred for suspected cardiac pseudoexudates; the evidence is less robust for hepatic hydrothorax. Display disagreement rather than forcing a diagnosis. [3]
Hemothorax Hematocrit Calculator
Divide pleural hematocrit by peripheral blood hematocrit. A ratio ≥0.50 supports hemothorax. Ratios of 0.25–<0.50 may occur after dilution and merit clinical assessment; 0.25 is not a universally validated cutoff. A lower ratio does not exclude bleeding. Use imaging and clinical assessment promptly when hemothorax is suspected. [4]
Thoracentesis Laboratory Checklist
Pair serum protein and LDH with pleural chemistry. Choose additional microbiology, cytology or targeted tests to answer the clinical question. Infection warrants attention to pH collection and cultures; suspected malignancy may need cytology and further investigation despite a negative result. The checklist above copies only the studies you select. [2][5]
Frequently Asked Questions
Can one positive criterion be enough?
Yes. A positive evaluable criterion identifies an exudate even while other measurements are missing. Three evaluable negative criteria are required for a transudative Light’s result.
Is the third ratio the patient’s serum LDH?
No. The second criterion uses the patient’s measured serum LDH. The third compares pleural LDH with two-thirds of the laboratory’s serum LDH upper limit of normal.
Does a high albumin gradient rule out infection or cancer?
No. A supporting gradient should prompt clinical interpretation, not automatic reassignment to a transudate.
References
- Light RW et al. Pleural effusions: the diagnostic separation of transudates and exudates. Ann Intern Med. 1972;77:507–513. ↗
- Roberts ME et al. British Thoracic Society Guideline for pleural disease. Thorax. 2023. ↗
- Bielsa S et al. Solving the Light’s criteria misclassification rate of cardiac and hepatic transudates. Respirology. 2012. ↗
- Zeiler J et al. Hemothorax: a review of the literature. Clin Pulm Med. 2020;27:1–12. ↗
- Rahman NM et al. Clinically important factors influencing the diagnostic measurement of pleural fluid pH and glucose. Am J Respir Crit Care Med. 2008;178:483–490. ↗
Prepared independently by MendelMD. Sources checked November 10, 2026.